TL95: Totalizer
TL95 "WISCO" Totalizer
- Linear totalization
- Selectable Input Signal
- High accuracy
Totalizer TL95 accepts standard current or voltage input and produce a pulse signal that drivers a totalizing counter. The output frequency is linearly propotional to the input signal. The output pulse can be scaled to represent gallons, barrels, litres, tons, BTU, KW/H or any other engineering unit, by selection of the proper output span. The count dropout is adjustable from 0 % to 20 % of full scale to eliminate false totalization of unwanted low level noise signals.
Specifications
Analog Input |
||||
Number of channel |
: | 1 Channel |
||
Input type |
: | Current, Voltage |
||
Input Range: |
: | Current (0 to 20, 4 to 20 mA) |
||
Voltage (1 to 5, 0 to 10 VDC)
|
||||
Digital Input |
||||
Number of Channel |
: | 1 Channels |
||
Output Type |
: | Pulse (Output Pulse compatable with external stardard electronic or electromechanied counter)c |
||
Output Range |
: | Pulse Range 25 to 51200 Count / Hour |
||
Linearity |
: | < ± 0.2 % of span. |
||
Drop Out |
: | 0 to 20 % of span. |
||
Power Requirements |
||||
Power Supply |
: | 110, 220 VAC |
||
24 VDC (Optional)
|
||||
Environmental Limits |
||||
Operating Temperature |
: | 0 to 55 °C |
||
Operating Humidity |
: |
5 to 95 %RH
|
||
Storage Temperature |
: | 0 to 70 °C |
||
Physical Characteristics |
||||
Dimension |
: | W50 x H70 x D130 mm. |
||
Mounting |
: | Wall or DIN rail |
||
Connection |
: |
Plug-in 11 pins socket
|
||
Warranty |
||||
Warranty Period |
: | 5 Year |
Contact Us
KDN AUTOMATION AND SERVICE CO.,LTD.
Tel : 02-023-3038, 082-550-3096
Line official : kdnautomation