TT98: Thermocouple Transmitter

TT98 "WISCO" Thermocouple Transmitter

  • Programmable range
  • Linearized output standard signal
  • 2 Isolated outputs
  • Isolation of input, output and power supply
  • Cold junction compensation

 

 

            Thermocouple Transmitter TT98 The thermocouple’s signal is linearized and cold – junction compensated to provide an isolated and linearized DC. voltage or current output. Typically the TT 98 interfaces with recording, monitoring or controlling instruments.

 

 

 

Specifications

 

Thermocouple Input

       
Number of channel

  :   1 Channel

Input type

  :   Thermocouple
Input range

  :   Type J 0 to 800 °C
        Type J 0 to 1200 °C
        Type R 0 to 1700 °C
        Type S 0 to 1700 °C
        Type T (-)200 to 200 °C
Cold junction compensation
  :   0 to 50 °C
Burn out thermocouple
  :  
Upscale drive standard

 

Analog Output

       
Number of Channel
  :   2 Channels
Output Type
   :   Current, Voltage 
Output Range
   :   Current (0 to 20, 4 to 20 mA)

        Voltage (0 to 1, 0 to 5, 1 to 5 VDC)

Linearity
   :   < ± 0.2% of span
Output Load Resistance
   :   Current (max. 1000 Ω load)

        Voltage (min 1000 Ω load)

Isolation voltage
  :  
500 VAC (1 min.) between input, output, power supply

  

Power Requirements

       
Power Supply
  :   100, 110, 220 VAC

       
24 VDC (Optional)

 

Environmental Limits

       
Operating Temperature

  :   0 to 55 °C 
Operating Humidity
   
5 to 95 %RH

Storage Temperature
  :   0 to 70 °C

 

Physical Characteristics

       
Dimension
  :   W50 x H70 x D130 mm.
Mounting

  :   Wall or DIN rail

Connection
  :   Plug-in 11 pins socket

 

Warranty

       
Warranty Period
    5 Year

 

 
  

Contact Us

KDN AUTOMATION AND SERVICE CO.,LTD. 

Tel : 02-023-3038, 082-550-3096

​Line official : ​​kdnautomation

E-mail: kdnautomation@gmail.com